ProblemĬan be caused by several things including broken diaphragms and airlocks, failure of motorised valves, issues with the thermostat or low water levels To help you understand some of the more common boiler problems, we've put together the list below which will also lets you know if you'll need an engineer or not. Which Ideal boiler problems need an engineer? Always hire a Gas Safe registered engineer who will be able to find the issue and either repair or replace the faulty component. If you don’t have a prepayment meter, or there’s plenty of credit, then the Ideal F2 error code isn’t something you should even attempt to fix yourself. If you use a prepayment meter then it’s worth double checking there’s enough credit. Issue with electrical components (pump, fan or PCB).Flame loss (F2 error code)įinding the reason behind your Ideal boiler suffering from flame loss is a tough one as there are so many possible causes: If you’d prefer a heating engineer took care of it, then don’t hesitate to hire one. Increasing boiler pressure is something you can do yourself, simply follow the steps in our guide to fixing boiler pressure. Over time, an Ideal boiler will very gradually reduce pressure but if there’s a sudden drop in pressure it’s likely that it will be down to a leak in the system or the radiators having recently been bled. Ideal boiler pressure should sit around the 1.5 bar mark, you can check this by taking a look at the built-in pressure gauge. If neither of these seem to be the cause of the issue then it's likely to be a problem within the appliance, possibly a zone valve issue. On Ideal combi boilers simply check that the hot water temperature is turned up on the front, then check that the isolation valve underneath the boiler on the cold mains pipe is vertical/open. This process is bound to cause some leakage, so it's a good idea to have a bowl underneath the boiler. The condensate trap will need to be removed so that the blockage can be cleared. If you're hearing a gurgling sound then the likely cause are blocked waterways from the boiler to the condensate. You don't expect your boiler to make a loud explosion and it can cause quite a scare, chances are that too much gas was in the chamber prior to ignition. If there is, it's then likely to mean that a component within the boiler may have failed, which an engineer will be needed for. If nothing is appearing on the boiler display then that suggests there's no power to the boiler. If you're unsure, an orange light will display on the boiler. This basically means that the boiler has shut down. When Ideal boilers attempt but fail to ignite 3 times, they’ll lockout. Common Ideal boiler problems Ideal boiler problems
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |